THE DRAWINGS CONTAINED IN THIS RECOMMENDATION HAVE BEEN DONE IN AUTOCAD Recommendation U.15 INTERWORKING RULES FOR INTERNATIONAL SIGNALLING SYSTEMS ACCORDING TO RECOMMENDATIONS U.1, U.11 AND U.12 (Malaga-Torremolinos, 1984) The CCITT, considering (a) that in international transit calls, a number of different signalling standards may be involved; (b) that interworking between signalling systems according to Recommendations U.1 and U.11 is already mostly covered by those Recommendations; (c) that it is necessary to define specifically the interworking rules between Recommendations U.1 or U.11 signalling and Recommendation U.12 signalling; (d) that it is also useful to cover in the same Recommendation any interworking problems between Recommendations U.1 and U.11 signalling standards; (e) that the originating Administration is responsible for international telex accounting; (f) that it is desirable for standard arrangements to apply for obtaining the called customer's answerback; (g) that it is essential to prevent alternative routing in transit centres if network identities cannot be conveyed to the originating centre; (h) that the use of type D signalling according to Recommendation U.12 should be considered in preference to type C (Recommendation U.11) signalling for transit working; (i) that types A and B (Recommendation U.1) signalling may only be used for transit working where no alternative routings are allowed; (j) that there may be cases where conversion of Network Identification Code (NIC) to a Transit Centre Identification Code (TCIC) or vice versa cannot be implemented. In such cases the TCICs and NICs shall be absorbed and alternative routing shall not be allowed within that transit centre. Onward selection shall indicate this condition by using the appropriate COT, unanimously declares the view that 1 General The rules for interworking should cover the following areas: - alternative routing, - conversion of TCIC (Recommendation U.11) and NIC (Recommendation U.12) signals, - service signal conversion, - exchange of line identifications, - call-connected signal conversion, - methods for obtaining the called subscriber's answerback. For the purposes of this Recommendation it shall be assumed that a typical type D interworking connection comprises a first and a last type D exchange and intermediate type D exchanges if any. These are defined below: A first type D exchange uses type D signalling on the outgoing side and any other trunk signalling standard or directly connected subscriber line standard on the incoming side. An intermediate type D exchange uses type D signalling on both the incoming and outgoing sides. A last type D exchange uses type D signalling on the incoming side and any other trunk signalling standard or directly connected subscriber line standard on the outgoing side. 2 Rules for alternative routing In general, alternative routing should not be allowed when the incoming circuit uses an A or B signalling standard. Table 1/U.15 gives details of each case. 3 Rules for conversion of TCICs and NICs (see Table 1/U.15 for details) Rule 1 - The last type D exchange should convert any TCIC received from outgoing type C circuits to the type D NIC format. Where a bilateral Fascicle VII.2 - Rec. U.15 PAGE1 agreement exists between Administrations to use TCICs on a type A signalling route, then these may be converted by the last type D exchange to the NIC format at the discretion of the Administration of that exchange. This requires that the TCIC must always use the standard Administration's identification letter(s) as recommended in Recommendation U.11, S 4 and defined in the ITU publication List of Indicators for the Telegraph Retransmission System and Telex Network Identification Codes, Part A (Recommendation F.60, S 3.4.2.4 refers). Rule 2 - Non-standard information, e.g. type A register codes will be absorbed by the last type D exchange. Such codes may also be received on type C circuits. It is therefore recommended that Administrations should, in no circumstances, return from terminating or transit centres any International Telegraph Alphabet No. 2 (ITA2) sequences which could be incorrectly interpreted as TCICs. Rule 3 - In the case of calls from type A or C circuits routed to type D circuits, the network identification codes (NICs) received from the type D network may be converted into the type C transit centre identification code (TCIC format) by the first type D exchange, see Table 1/U.15. The NICs received from the type D network will be translated into the TCIC format of ITA2 Combination No. 29, followed by recommended in Recommendation F.60) followed by number of Combinations No. 30 to complete a sequence of seven combinations. Rule 4 - In the case of calls from type B circuit routing to a type D circuit, the first type D exchange shall absorb any NICs. poss possible call connected signal and answerback timing problems The conversion from 3 or 4 character NICs to 7 character TCICs can result firstly in the callVconnected signal arriving at the first type D centre before complete transmission of the last TCIC, and secondly, in some cases, the answerback arriving before complete transmission of the callVconnected signal to the incoming circuit. It is necessary to overcome this difficulty by delaying the forwarding of selection in relation to the activities on the backward path. The third COT character should be sent by the first type D exchange to indicate (by bit b1) to the following type D exchanges that a delay of forward selection is necessary, since the call has been received from a nonVtype D signalling standard for which conversion of NICs to TCICs is required. Figure 1/U.15 shows the timing diagram of this protocol. Note 1 V TCICs received from distant type C links would pass through the type D links with the appropriate conversion. Where the third COT indicates that conversion of NIC to TCIC is necessary, onward seizure should not occur before the complete transmission of CSC No. 12 of the locally generated NIC. Where the conversion of NIC to TCIC is not necessary, onward seizure of the outgoing circuit should not occur before the complete transmission of the receptionVconfirmation signal. Note 2 V A problem may exist where the same Recommendation F.69 code is allocated to more than one RPOA. 5 Rules for service signal conversion Rule 1 V The last type D exchange will convert all returned standard service signals into the appropriate type D numeric service codes. In the case of additional information included in the service text (i.e. a, d, g, d preceding a Recommendation U.1 type A or B service code (see Recommendation U.1, ' 10.1.2)), only the standard Recommendation U.1/U.11 service text will be translated by the type D transit centre. Table 7b/U.12 gives details of service signal conversion. 6 Rules for exchange of line identifications Rule 1 V If the incoming circuit is not a subscriber line then the first type D exchange shall not request a called line identification. Rule 2 V When the incoming circuit is not a subscriber line and a request for calling line identification is received, the first type D exchange shall send CSC No. 12 only, to indicate that no identification is available as per Table 1/U.12. Rule 3 V If the incoming circuit is a subscriber line and the called line identification is required, then the first type D exchange shall recognize PAGE6 Fascicle VII.2 - Rec. U.15 receipt of the callVconnected signal not preceded by a STTC and a TTC signal as an indication that a called line identification is not available. Rule 4 V If the outgoing circuit is not a subscriber line, then the last type D exchange shall not request a calling line identification. Rule 5 V When the outgoing circuit is not a subscriber line and a request for called line identification is received, the last type D exchange shall indicate that the identification is not available, as described in Recommendation U.12, S 3.13. 7 Rules for call connected signal conversion Rule 1 - The last type D exchange shall convert all variations of received call connected signals as defined in Recommendations U.1 and U.11 to the type D call connected signal, indicating that call metering is required (CSC No. 13). Rule 2 - The first type D exchange shall convert CSC No. 13 to the call connected signal according to Recommendations U.1 or U.11. Rule 3 - CSC No. 14 (call connected without metering) received at the first type D exchange may or may not be converted to a call connected on type A, B or C circuits. The use of CSC No. 14 is left for further study. 8 Rules for obtaining the called subscriber's answerback when interworking type D with other signalling systems Rules 2 to 4 apply to the first type D exchange and Rules 5 to 7 to the last type D exchange. A compilation of the rules is shown in Tables 2/U.15 and 3/U.15. Rule 1 - As a general rule, the first and the last type D exchanges should behave independently of each other's interworking requirements with regard to controlling the answerback tripping, and intermediate exchanges will be transparent to this control. Rule 2 - For locally connected subscribers the first type D exchange will generate the WRU on receipt of the call connected signal as per Recommendation U.12, Appendix III. Rule 3 - If the incoming circuit uses an automatic return of answerback trunk signalling standard, then the first type D exchange will generate a WRU two seconds after receipt of the call connected signal. Rule 4 - If the incoming circuit uses a nonautomatic return of answerback trunk signalling standard, then the first type D exchange will through-connect on receipt of the call connected signal without generating a WRU. Rule 5 - For locally connected subscribers, the last type D exchange will through-connect after the call connected signal has been transmitted on the incoming type D trunk. Rule 6 - If the outgoing circuit uses an automatic return of answerback trunk signalling standard, then the last type D exchange will absorb any incoming characters on the forward path until two seconds from the commencement of the first backward path character. If no characters have been received on the backward path within 8-9 seconds following the start of the received call connected signal, then through-connection shall occur. The alternative of clearing the call is for further study. Rule 7 - If the outgoing circuit uses a nonautomatic return of answerback trunk signalling standard, then the last type D exchange shall delay any received WRU until two seconds from the start of the received call connected signal. Through-connection shall occur following the retransmission of the WRU or after two seconds from the start of the received call connected signal if no WRU has been received. TABLE 1/U.15 Rules for conversion of network identification codes (NICs) and transit centre identification codes (TCICs) and alternative routing Incoming Outgoing Action to be taken by the transit exchange signalling signalling Type D The NIC shall be retransmitted as received. Alternative routing is allowed. Type C TCICs shall be converted into NICs. Any type A register codes shall be absorbed. Alternative routing is allowed. Type D Type B No register codes will be received. Alternative routing is not allowed (see Note). Type A with Absorb register codes. Alternative routing is register codes not allowed (see Note). Type A with TCICs may be absorbed or converted to NICs at TCICs the discretion of individual Administrations. Alternative routing is not allowed (see Note). Type D NICs shall be converted into TCICs. Alternative routing is allowed. Type C with TCICs shall be retransmitted as received. register codes The type A register codes may be or TCICs retransmitted as received at the discretion of individual Administrations. Alternative routing is allowed. Type C Type B No register codes will be received. Fascicle VII.2 - Rec. U.15 PAGE1 Alternative routing is not allowed (see Note). Type A with The register codes may be absorbed or register codes retransmitted as received at the discretion of individual Administrations. Alternative routing is not allowed (see Note). Type A with The TCICs may be absorbed or retransmitted as TCICs received at the discretion of the individual Administration. Alternative routing is not allowed (see Note). Type D Any received NICs shall be absorbed. Alternative routing is not allowed (see Note). Type C with Any received register codes or TCICs shall be Type B register codes absorbed. Alternative routing is not allowed or TCICs (see Note). Type B No register codes will be received. Alternative routing is not allowed (see Note). Type A with Any received register codes or TCICs shall be register codes absorbed. Alternative routing is not allowed or TCICs (see Note). PAGE6 Fascicle VII.2 - Rec. U.15 TABLE 1/U.15 (continued) Incoming Outgoing Action to be taken by the transit exchange signalling signalling Type D Conversion of NICs to TCICs is at the discretion of individual Administrations. Alternative routing can be allowed only if conversion of NICs to TCICs occurs. Type A using a Type C with The received register codes or TCICs may be TCIC (trunk register codes absorbed or retransmitted at the discretion route dedicated or TCICs of individual Administrations. Alternative to originating routing is allowed only if retransmission of traffic only) TCICs occurs. Type B No register codes will be received. Alternative routing is not allowed (see Note). Type A with Any received register codes or TCICs may be register codes absorbed or retransmitted as received at the or TCICs discretion of individual Administrations. Alternative routing is not allowed (see Note). Type D NICs will be absorbed. Alternative routing is not allowed (see Note). Type B No register codes will be received. Alternative routing is not allowed (see Note). Type A using Type C with The received register codes or TCICs may be register codes register codes absorbed or retransmitted, at the discretion (trunk route or TCICs of the individual Administrations. dedicated to Alternative routing is not allowed (see originating Note). traffic only) Type A with The received register codes or TCICs may be register codes absorbed or retransmitted as received, at the or TCICs discretion of individual Administrations. Alternative routing is not allowed (see Note). Type D NICs may be absorbed or converted to TCICs, at the discretion of individual Administrations. Alternative routing is not allowed (see Note). Type A with Type C with register codes or TCICs Fascicle VII.2 - Rec. U.15 PAGE1 register codes Register codes or TCICs may be absorbed or or TCICs retransmitted as received, at the discretion of individual Administrations. Alternative routing is not allowed (see Note). Type B No register codes will be received. Alternative routing is not allowed (see Note). Type A with Register codes or TCICs may be absorbed or register codes retransmitted as received at the discretion or TCICs of individual Administrations. Alternative routing is not allowed (see Note). Note - Where alternative routing is stated as "not allowed", it applies in this transit exchange and shall also be indicated in the COT signals on outgoing type C and D signalling to prevent alternative routing in distant centres. Alternative routing is not allowed when the outgoing or incoming trunks use type A or B signalling, with the one exception of the case where a type A incoming route accepts TCICs and is dedicated to originating traffic only and where the outgoing signalling is type C or D standard. PAGE6 Fascicle VII.2 - Rec. U.15 TABLE 2/U.15 Rules for obtaining the called subscriber's answer-back (first type D exchange) Incoming Action to be taken by the first type D Outgoing signalling type exchange signalling type Type A, 1. Send WRU two seconds after receiving Type B call-connected signal. (automatic 2.Connect-through backward path after Type D return of sending the call-connected signal. answer-back), 3.Connect-through forward path after sending Type C WRU. (See S 8, Rule 3 and Note below) Type B, 1.No action on WRU. (non-automatic 2.Connect-through backward path after Type D return of sending call-connected signal. answer-back) 3.Connect-through forward path after receiving call-connected signal. (See S 8, Rule 4) 1. Send WRU 1-2 character periods after Type D Subscriber receiving call-connected signal. 2.Connect-through backward path after receiving call-connected signal. 3.Connect-through forward path after sending WRU. (See S 8, Rule 2 and Note below) Note - Where a call is recognised as originating from a service position (either as indicated by the COT received or derived from the use of dedicated service trunks or lines), then individual Administrations may at their discretion inhibit the generation of the WRU at the first type D exchange. Fascicle VII.2 - Rec. U.15 PAGE1 TABLE 3/U.15 Rules for obtaining the called subscriber's answer-back (last type D exchange) Incoming Action to be taken by the first type D Outgoing signalling type exchange signalling type 1. Absorb WRU and any other characters on the forward path until through-connection of the forward path. Type D 2.Connect-through the backward path after sending the call connected signal and in Type A, the case of type C on completion of the Type B received call-connected signal. (automatic 3.Connect-through the forward path two return of seconds after reception of the first answer-back), backward path characters following the Type C received call-connected signal or in the absence of any characters, 8-9 seconds after the start of the received call-connected signal. (See S 8, Rule 6) 1. Delay any received WRU until two seconds after the start of the received Type D call-connected signal. Type B 2.Connect-through the backward path after (non-automatic sending the call- connected signal. return of 3.Connect-through the forward path after answer-back) retransmitting any received WRU, or in the absence of a received WRU, two seconds after the start of the received call-connected signal. (See S 8, Rule 7) 1.No action on WRU. 2.Connect-through backward path after Type D sending call-connected signal. Subscriber 3.Connect-through forward path after sending call-connected signal. (See S 8, Rule 5) Figure 1/U.15 - CCITT 67820 PAGE6 Fascicle VII.2 - Rec. U.15